Changes

Jump to navigation Jump to search
no edit summary
Line 9: Line 9:     
<big>''' Abstract </big>'''
 
<big>''' Abstract </big>'''
 
+
<div style="text-align:justify;">
 
[[Netrabastivyapat Siddhi]] deals with possible complications during ''basti'' procedure, due to improper choice of ''netra'' (injection pipe/nozzle) and ''bastiputaka'' (medicinal bag) as well as their inappropriate handling during the course of action by the ''praneta'' (administrator). The total number of improper ''bastinetra'' to be avoided are eight and the consequent ''dosha''( defects) are also eight. Also, abnormal ''bastiputaka'' to be avoided while the procedure as well as their corresponding ''dosha'' are eight in number. ''Pranetradosha'' (administrator error) are ten in number and they are categorized into ''pranayana'' (introduction of ''netra''), ''baddha'' (filling and tying of ''basti'') and ''peedana'' (squeezing of ''basti'') ''dosha'' respectively.
 
[[Netrabastivyapat Siddhi]] deals with possible complications during ''basti'' procedure, due to improper choice of ''netra'' (injection pipe/nozzle) and ''bastiputaka'' (medicinal bag) as well as their inappropriate handling during the course of action by the ''praneta'' (administrator). The total number of improper ''bastinetra'' to be avoided are eight and the consequent ''dosha''( defects) are also eight. Also, abnormal ''bastiputaka'' to be avoided while the procedure as well as their corresponding ''dosha'' are eight in number. ''Pranetradosha'' (administrator error) are ten in number and they are categorized into ''pranayana'' (introduction of ''netra''), ''baddha'' (filling and tying of ''basti'') and ''peedana'' (squeezing of ''basti'') ''dosha'' respectively.
    
'''Keywords''': ''Netra, basti, praneta, dosha'' and ''siddhi'', nozzle, insertion, injection of enema, impediments.  
 
'''Keywords''': ''Netra, basti, praneta, dosha'' and ''siddhi'', nozzle, insertion, injection of enema, impediments.  
 +
</div>
    
{{Infobox
 
{{Infobox
Line 30: Line 31:     
== Introduction ==
 
== Introduction ==
 
+
<div style="text-align:justify;">
 
The preceding chapter ([[Snehavyapat Siddhi]]) dealt with the management strategies for ''snehabastivyapat'' and therefore this chapter elucidates the ''vyapat'' (complications) related to the instrumentation involved in either kind of ''basti''. ''Netra'' (nozzles designed for enema) and ''basti'' (bag designed for enema) that are to be avoided in procedures and ''vyapat'' (complications) arising due to inappropriate appliance of ''netra'' along with their management are explained in the chapter.
 
The preceding chapter ([[Snehavyapat Siddhi]]) dealt with the management strategies for ''snehabastivyapat'' and therefore this chapter elucidates the ''vyapat'' (complications) related to the instrumentation involved in either kind of ''basti''. ''Netra'' (nozzles designed for enema) and ''basti'' (bag designed for enema) that are to be avoided in procedures and ''vyapat'' (complications) arising due to inappropriate appliance of ''netra'' along with their management are explained in the chapter.
   Line 504: Line 505:     
As discussed earlier, with the knowledge of ''siddhi'' one acquires not only routine practice but expertise in prevention, identification, rectification and management of complications related to the respective ''karma''.(Verse 19)
 
As discussed earlier, with the knowledge of ''siddhi'' one acquires not only routine practice but expertise in prevention, identification, rectification and management of complications related to the respective ''karma''.(Verse 19)
 
+
</div>
    
== References ==
 
== References ==

Navigation menu